We’ve been providing expert led fire suppression systems to buses and coaches for over 30 years. Our systems are designed for dependable performance, supported by specialist engineers who understand the demands of operating a fleet, along with independent testing to UNECE R107 requirements for engine compartment protection.
Understanding fire risks in buses and coaches
Buses and coaches contain high-temperature components and combustible materials, often in areas that are difficult for the driver to monitor. These risks vary with vehicle design, fuel type and operating conditions.
Common fire hazards include:
- Engine compartments: Turbochargers, exhaust manifolds and other components can reach temperatures capable of igniting nearby materials.
- Fuel and fluid leaks: Damaged pipes, hoses and connections can allow combustible fluids to reach hot surfaces.
- Electrical systems: Faulty wiring, damaged connections and overheating components can create ignition risks.
- Battery and power systems: Electric and hybrid vehicles introduce additional electrical equipment requiring careful assessment and suitable protection.
- Restricted access: Fires developing in rear engine compartments or enclosed equipment areas may go unnoticed until they have progressed.
It is the legal duty of a bus operator, coach provider, or other responsible person(s) to identify the hazards listed above and prevent a fire from occurring in the first place.
How our vehicle fire suppression systems work
Our automatic systems are configured around each vehicle's identified fire hazards. They combine electronic heat detection, controlled activation and targeted dry chemical discharge to help contain a fire quickly.
Fire detection
Linear Heat Detection (LHD) cable is installed around identified fire-risk areas, including high-temperature components within the engine compartment. When the cable reaches its activation temperature, it sends a fire signal to the Ardent control module. The electronic system also monitors the detection circuit for faults or damage. This helps maintain reliable operation in vehicles exposed to constant vibration and changing temperatures, while avoiding unwanted discharges associated with pressure loss in pneumatic detection systems.
System activation
The control module then receives the fire signal and automatically initiates suppression, providing an immediate response to a fire that may be developing beyond the driver's view. The system can also communicate with compatible vehicle equipment, including our Vehicle Multi-Messaging System (VMMS). Where fitted, this allows spoken warnings to be delivered for fire detection, system activation and relevant faults. Additional temperature sensors can provide early warnings when abnormal heat is identified.
Targeted agent discharge
On activation, ABC dry chemical is released through distribution hoses and nozzles positioned around the potential fire hazards. The agent provides rapid flame knockdown and disperses through the engine compartment to reach vulnerable areas. We establish nozzle positions and the quantity of agent required through a vehicle-specific fire hazard assessment. This ensures the installation provides appropriate coverage for the identified hazards and the relevant UNECE R107 approval requirements.
Introducing our Transport Safety Systems
Alongside vehicle fire suppression, we also provide a range of transport safety systems across VMMS, driver communication, hearing loops and safety announcement systems.
Driver communication
Background noise and protective cab screens can make conversation difficult. Our hands-free intercom helps drivers and passengers hear each other clearly.
Vehicle messaging system
Drivers need to hear important warnings without taking their eyes off the road. VMMS gives drivers and passengers clear spoken messages through separate speakers.
Hearing loop
Background noise can make stop and route announcements difficult to hear. ClearConnect™ sends speech directly to compatible hearing aids and cochlear implants.
Safety announcements
Sudden braking can cause passengers to lose their balance on stairs or when getting up. SafeStep™ gives them timely reminders to hold the handrail or stay seated until the bus stops.
Acoustic vehicle alerting system
Electric and hybrid buses can be hard to hear at low speeds. Our V-AVAS gives pedestrians an audible warning that changes with the vehicle’s speed.
Independently tested to UNECE R107 requirements
Our approved bus and coach fire suppression system meets the applicable automatic engine compartment fire suppression requirements of UNECE Regulation No. 107.
The system has undergone independent fire testing by the Research Institutes of Sweden (RISE), using test procedures adopted from SP Method 4912.
We carry out a fire hazard assessment for each vehicle specification, helping manufacturers and operators select an appropriate system configuration and address relevant approval requirements.
Training
People working with safety equipment need to know what to check and how to respond when something goes wrong. Ardent Academy provides practical training tailored to their roles.
Service & support
Providing ongoing servicing, maintenance, technical advice and responsive support throughout the lifetime of every installation.
Let's discuss your fire protection requirements