Electric Vehicle Charging Fire Suppression Systems
Electric vehicle charging protection is increasingly critical as operators invest in high-value charging infrastructure and seek to protect operations, revenue, and insurance exposure. Fire and electrical incidents within EV charging systems can result in significant asset damage, operational downtime, and increased insurance premiums - making proactive protection a commercial necessity rather than an optional safeguard.
Ardent’s Electric Vehicle Charging Fire Suppression Systems are specifically engineered to protect high-value EV charging infrastructure. By incorporating an automatic clean agent fire suppression system, the cabinet delivers rapid, residue-free fire control without causing damaging to sensitive electrical components. Designed for AC and DC electric vehicle charging installations, it provides a robust, insurer-aligned solution that supports operational continuity, asset protection, and risk reduction across public, commercial, and fleet charging environments.
Electrical Fire Risks
Short circuit
Overloaded components
Faulty wiring
Electrical surges
Within electric vehicle charging installations, fire incidents inside electrical cabinets can be difficult to detect at an early stage. Fires can develop internally and remain unnoticed until smoke or heat escapes the enclosure. Where charging infrastructure is located in unattended or remote environments, an incident may continue to grow until it is detected by external or passive fire detection systems-by which point damage to critical charging and control equipment can be extensive.
Ardent’s Electric Vehicle Charging Systems incorporate automatic fire detection and suppression, enabling rapid response without the need for human intervention. Installed directly within the electrical cabinet, the system targets fire risks at the source, minimising damage to high-value charging assets and reducing operational disruption.
The automatic clean agent fire suppression system provides a cost-effective and reliable solution. Following system activation, reinstatement is quick and straightforward, supporting rapid return to service.
Why choose Ardent Fire Suppression Systems?
-
Automatic fire suppression specialists
Our fire suppression systems ensure reliable, automatic fire detection and actuation.
-
Cost-effective fire protection
With easy installation, our systems can be quickly reinstated after deployment - minimising downtime.
-
Clean agent
Our electrical panel fire suppression systems use clean agents - non-corrosive, non-conductive, and safe to people.
-
Flexible solutions
With more than 30 years of experience, we are industry experts and tailor our solutions to your bespoke business needs.
-
Complete peace of mind
From start to finish, we take care of all aspects of your fire detection and suppression needs.
Want us to give you a call?
Request a CallbackHow our fire detection and suppression systems work
1. The pressure gauge confirms readiness
The pressure gauge located on the cylinder valve will be visible in the green segment to confirm the pressure of the system is adequate and ready for normal use.
2. Detects high temperatures, fast
The detection tubing is pressurised with nitrogen, rupturing when exposed to the heat generated by a fire and initiating the release of the suppression agent. If a pressure switch is fitted to the system, this loss of pressure can also be used to trigger peripherals such as alarms or sounders.
3. Suppresses in seconds
By targeting the heart of the fire at the point of rupture, the suppression agent gets to work in a matter of seconds. It evaporates cleanly after deployment, without leaving residue, and automatically suppresses the source of heat.
4. Shuts down mains power to the charger
As the suppression agent is released, the system shuts down the main power to the charger to reduce the potential for re-ignition.
5. Flashing beacon alerts operators
The beacon is powered by an internal battery system and provides a continuous alert that the system has deployed.
Why use clean suppression agents for Electric Vehicle charging protection?
Selecting the correct fire suppression agent is critical to the effective protection of electric vehicle charging infrastructure and electrical cabinets. For EV charging protection systems, clean agent fire suppression provides rapid, targeted fire control by removing heat at the source - suppressing fires within seconds of detection.
The clean agent discharges and evaporates without leaving residue, eliminating the need for post-discharge clean-up and preventing secondary damage to sensitive EV charging and electrical components. As a non-conductive and non-corrosive solution, clean agent fire suppression is ideally suited for use within electrical cabinets, power distribution units, and EV charging control panels.
By protecting high-value electric vehicle charging infrastructure without disrupting equipment integrity, clean agent fire suppression supports operational continuity, asset longevity, and insurer-aligned risk reduction across public, commercial, and fleet charging environments.
How we deliver
At Ardent, we take care of every step of the process to ensure both electrical equipment and personnel are protected against the risk of fire 24/7. From understanding the fire hazards specific to each organisation’s equipment and environment, to our rapid response to emergencies, businesses can rest assured our electrical panel fire suppression systems will deliver the highest level of protection required.